EasyManuals Logo

Siemens SCALANCE X-200 Series User Manual

Siemens SCALANCE X-200 Series
Go to English
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Technical Specifications
7.1 Technical specifications
SCALANCE X-200
100 Compact Operating Instructions, 12/2010, A5E00813159-11
Table 7- 7 Permitted cable lengths (fiber-optic)
Device type
SCALANCE
1 - 50 m
980/1000 plastic
optical fiber (POF)
1 - 100 m
200/230 polymer cladded
fiber (PCF)
6 dB max. permitted FO
cable attenuation with 3 dB
link power margin
0 - 4000 m
Glass FO cable 50/125 µm
glass fiber;
0 - 5000 m
Glass FO cable 62.5/125 µm
glass fiber;
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted FO
cable attenuation with 3 dB
link power margin
0 - 26000 m
glass FOC
10/125 µm single mode fiber; 0.5
dB/km at 1300 nm;
13 dB max. permitted FO cable
attenuation with 2 dB link power
margin
XF204 - - - -
X208 - - - -
XF208 - - - -
X216 - - - -
X224 - - - -
X204-2 - - + -
XF204-2 - - + -
X206-1 - - + -
XF206-1 - - + -
X212-2 - - + -
X204-2LD - - - +
X206-1LD - - - +
X212-2LD - - - +
X202-2IRT - - + -
X204IRT - - - -
XF204IRT - - - -
X204 IRT PRO - - - -
X202-2P IRT PRO + + - -
X201-3P IRT PRO + + - -
X202-2P IRT + + - -
X201-3P IRT + + - -
X200-4P IRT + + - -
Table 7- 8 MTBF
Device type
SCALANCE
Degree of protection MTBF
XF204 IP20 48.03 years
X208 IP30 83.71 years
XF208 IP20 54.80 years
X216 IP30 52.07 years
X224 IP30 45.87 years
X204-2 IP30 74.64 years
XF204-2 IP20 43.58 years