EasyManuals Logo

Siemens SCALANCE X-200 Series User Manual

Siemens SCALANCE X-200 Series
Go to English
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
Technical Specifications
7.1 Technical specifications
SCALANCE X-200
102 Compact Operating Instructions, 12/2010, A5E00813159-11
Device type
SCALANCE
Operating temperature Storage/transport
temperature
Relative humidity in
operation
Operating altitude at max. xx°C
ambient temperature
XF206-1 *) -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X212-2 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204-2LD -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X206-1LD -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X212-2LD -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X202-2IRT -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204IRT -40 °C to +70 °C -40 °C to +60 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
XF204IRT *) -40 °C to +60 °C -40 °C to +60 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204 IRT PRO -25 °C to +70 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X202-2P IRT
PRO
-25 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X201-3P IRT
PRO
-25 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X202-2P IRT -25 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X201-3P IRT -25 °C to +50 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 45 °C
3000 m at max. 40 °C
X200-4P IRT -25 °C to +40 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 35 °C
3000 m at max. 30 °C
Note
*) Remember the installation orientation of the IE Switch XF-200
if the IE Switch XF-200 is installed horizontally, a maximum ambient temperature of +40 °C
is permitted.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-200 Series and is the answer not in the manual?

Siemens SCALANCE X-200 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-200 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals