NCK alarms
11/2006 Overview of Alarms
2-53
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
4240 Runtime overflow for IPO cycle or position controller cycle, IP %1
Parameters: %1 = Program location
Definitions: The settings for the interpolation and position control cycle were modified before the last power-up
such that too little computing time is now available for the requisite cyclic task.
The alarm occurs immediately after power-up if too little runtime is available even when the axes are
stationary and the NC program has not started. However, task overflow can occur only when
computation-intensive NC functions are called during program execution.
Reaction: NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Alarm reaction delay is canceled.
Remedy: Please inform the authorized personnel/service department. Take greater care when optimizing the
clock times NCK MD 10050 SYSCLOCK_CYCLE_TIME, MD 10060
POSCTRL_SYSCLOCK_TIME_RATIO and/or MD 10070 IPO_SYSCLOCK_TIME_RATIO.
The test should be performed with an NC program that represents the worst case. For safety, a margin
of 15 to 25% should be added to the times determined in this way.
Program
Continuation:
Switch control OFF - ON.
4250 FastPlcCom functionality not available
Definitions: This alarm indicates that the PLC provides the None FastPlcCom functionality during start-up
although this functionality is requested by the NCK.
Reaction: Alarm display.
Remedy: Retrofit the PLC with the FastPlcCom functionality or deactivate the FastPlcCom functionality by
means of NCK machine data.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
4252 PLCIO read error: %1
Parameters: %1 = PLCIO error code
Definitions: This alarm indicates that errors occured when reading the PLCIO with the FastPlcCom functionality.
Reaction: Alarm display.
Remedy: Check machine data MD 10394/10395 or check the PLC hardware configuration.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
4254 PLCIO write error: %1
Parameters: %1 = PLCIO error code
Definitions: This alarm indicates that errors occured when writing on the PLCIO with the FastPlcCom functionality.
Reaction: Alarm display.
Remedy: Check machine data MD 10396/103947 or check the PLC hardware configuration.
Program
Continuation:
Clear alarm with the RESET key. Restart part program

Other manuals for Siemens Simodrive 611

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Related product manuals