5.Refrigeration/ freezing temperature display lamp
6.Refrigerating chamber indicator lamp
7.Freezing chamber indicator lamp
8.Refrigeration/ freezing chamber temperature setting key
9.Chamber selection setting key
Display the temperature set up for the refrigeration/ freezing chamber, and display in a circular
way at the frequency of 1Hz.
When the temperature set up for the refrigerating chamber is displayed, and the refrigeration
chamber indicator lamp will turn on.
When the temperature set up for the freezing chamber is displayed, the freezing chamber
indicator lamp will turn on.
Press “Room” key to select “Refrigeration”, and the refrigeration temperature display area will
display originally set temperature, and flicker at the frequency of 1Hz; press “Temperature” key
for every one more time, the setting will change in a circular way as per 23…8 OF
2 3 … 8 OF; if there is no key-pressing operation within 5s or the “Room” key is
pressed once more to enter into the setting of other room, the indicator lamp will stop
flickering, and the setting will take effect.
If the refrigerator is set up to be OF, the refrigerator will stop refrigerating.
Press “Room” key to select “Freezing”, and the freezing temperature display area will display
originally set temperature and flicker at the frequency of 1Hz; press “Temperature” key for
every one more time, the setting will change in a circular way as per -25 -16 -
15 -25 -16 -15; if there is no key-pressing operation within 5s or the “Room”
key is pressed once more to enter into the setting of other room, the indicator lamp will stop
flickering, and the setting will take effect.
Touch “Room” key lightly, and the current room indicator lamp will turn on and flicker at the
frequency of 1Hz. Press “Room” key for every one more time, the indicator lamp will change
circularly between refrigeration chamber and freezing chamber. If there is no key-pressing
operation within 5s, the setting will be defaulted confirmed and will take effect.
Fault Code Display
Fault display code
RS
FS
Fd
ES
FF
UC
Fault items
Failure of the sensor in the refrigeration chamber
Failure of the sensor in the freezing chamber
Failure of sensor for defrosting of freezing chamber
Failure of ambient temperature sensor
Fan failure
Communication failure
49

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Signature SRB3103A+XNF and is the answer not in the manual?

Signature SRB3103A+XNF Specifications

General IconGeneral
BrandSignature
ModelSRB3103A+XNF
CategoryRefrigerator
LanguageEnglish

Related product manuals