If an abnormality comes up, the induction hob will enter the protective state
automatically and display corresponding protective codes:
Problem Possible cause What to do
No pot or pot not
suitable
Replace the pot
E2/E3
Abnormal supply
voltage
Please inspect whether power
supply is normal. Power on after
the power supply is normal.
E4/E5
Temperature sensor of
the IGBT failure
Please contact the after-sales
service.
E7/E8
Temperature sensor
failure
Please contact the after-sales
service.
E6/E9
Bad induction hob
heat radiation
Please restart after the induction
hob cools down.
Eb/EC
PCBA communication
failure
Please contact the after-sales
service.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and
damages to the induction hob.
Model identification STI4F 2FLEX
Cooking Zones 4 Zones
220-240V~/380-415V 2N~
Installed Electric Power 7200W
Product Size D x W x H (mm) 590×520×60
Building-in Dimensions A x B (mm) 560×490
TECHNICAL SPECIFICATION