INSTALLATION & MAITENENCE
This product must be installed in strict accordance with local plumbing
codes. A licensed plumber should install product.
**Visit: www.thesilentvenus.com/our-system for instructional videos**

Questions and Answers

  • J
    Jessica RobertsAug 4, 2025
    How to fix Silent Venus Toilets motor humming but not clearing?
    • S
      Stephanie MaloneAug 4, 2025
      If the Silent Venus toilet motor is humming but not clearing, it could be due to a blockage in the unit, possibly from something other than toilet paper or a blocked outlet. First, disconnect the unit from power. Drain the toilet bowl and macerating unit using a siphon. Remove the bowl and check for obstructions. If none are found, remove the unit's lid, then remove the rubber tank and motor as a unit. Disconnect the motor from the tank, loosen the screws on the motor pump, and remove any blockage. Reassemble and reconnect the unit.
  • J
    John OconnorAug 12, 2025
    What to do if Silent Venus Toilets motor runs inconsistently?
    • D
      Daniel HeathAug 12, 2025
      If the Silent Venus toilet motor runs inconsistently, it might be due to a blockage in the outlet pipe. To resolve this, lift off the lid and check the check valve for any foreign objects. Insert a short length of pipe into the outlet, directing it into a bucket. Then, flush the toilet to see if the unit operates correctly without stopping.
  • A
    Andrea FisherAug 18, 2025
    Why Silent Venus SVP600 motor is silent?
    • B
      Brian MillerAug 18, 2025
      If your Silent Venus toilet motor is silent, it may be due to a loss of power or a faulty pressure switch. Check if the unit is properly connected to an electrical supply. If it is, the issue may be with the motor itself.
  • C
    christophermcclainAug 26, 2025
    How to troubleshoot Silent Venus SVP600 Toilets pressure switch not working?
    • T
      toddgreenAug 27, 2025
      If the pressure switch on your Silent Venus toilet is not working, the cause may be a faulty switch. Begin by checking the small plastic pipe covering the switch for any blockages. Remove the plastic pipe to access the switch. Test the pressure by using a rubber ball to create pressure. If you hear a click, the switch is working; ensure the unit is connected to a power source, which should start the motor.

Summary

Standard Operation

Electric Requirements

Sanitary Inlets

Sewer Pipe Connection

Pre-Installation Tips

Gravity Fall

Ensures positive gravity fall for all inlet pipe work and horizontal piping for free drainage.

Vertical Installation First

Specifies that any required vertical lift must precede the horizontal pipe run.

Directly Vertical

Advises making vertical lifts direct and limiting initial horizontal runs before a vertical lift.

Pipe Supports

Emphasizes supporting pipe work to prevent blockages from residual solids.

Three Foot Minimum

Requires unit installation at least 3 feet from the soil stack for efficient waste reduction.

Pipe Work

Placement Options

Installation Instructions

Step 6 Activating the Unit

Guides on removing debris, filling the tank, turning on power, and testing the unit.

Normal Operating Procedures

Troubleshooting Guide

Motor Humming, No Clearing

Addresses blockages causing motor hum without clearing waste from toilet and fittings.

Silent Motor

Covers issues like loss of power or faulty pressure switch affecting motor operation.

Pressure Switch Not Working

Explains troubleshooting steps for a non-functional pressure switch.

Disassembly for Small Fixes

Impeller Check

Cutter Blades

Reassembly of the Lid

Silent Venus SVP600 Specifications

General IconGeneral
BrandSilent Venus
ModelSVP600
CategoryToilets
LanguageEnglish