11
You can find the data knowing the address of the router (192.168.xxx.xxx) and by entering it into the browser when a PC is connected to the Wi-Fi. You can also download Apps
such as "Fing" and "Netlook" to display local networks, identify the useful one and see the IP address as well as the other required data. When the control panel is properly
connected, connection will display top left of the screen. If it does not display, check that data is accurate and restart the system (Tools → Restart).
Caution! Select: Other Transmission Parameters → Enable Internet Connection: no connections can take place if option is not enabled!
7.3) Connecting as Access Point
SSID: is automatically displayed and can be changed
IRC Channel: channel 1 is supplied (change from 2 to 13 if 1 is not available)
Wi-Fi MAC interface: is automatically displayed
Local Network Authentication: select a mode to be safe
Control Panel IP: is automatically supplied and can be changed if required
Wi-Fi Password: enter pw for local Wi-Fi network that has been setup
Beginning IP: is automatically supplied and can be changed if required
Wi-Fi Region: press and select the appropriate one
Subnet Mask: 255.255.255.0 is supplied
Wi-Fi Protocol: is automatically displayed
End IP: is automatically supplied and can be changed if required
Caution! Beginning IP: the Control Panel supplies a beginning IP which should be changed only if other device use the same address. We recommend not changing the supplied IP
address or, at any rate, avoid to use endings with digits that are less than 10 in order to keep 10 positions available for cameras and/or PhotoPir devices.
Caution! In this mode, you can only receive video frames of alarm events as e-mail attachments (setup relevant window) while same cannot be requested until the software
update described in item 7.0 is available.
Caution! Select: Other Transmission Parameters → Enable Internet Connection: no connections can take place if option is not enabled!
7.4) Silentron APP : two App are free available on Google Playstore. View the demo, then setup the right App on the Smartphone.
7.4.1) App SILENYA ADV : free App for both iOS and Android; local & remote use with a Client programmed Panel , local use only with an Access Point programmed panel.
ID - Local network address: it is the same one used for the control panel
Description: enter the name of the system (any text)
Serial Number: select Control Panel Parameters → SN CP (serial number control panel) to display it on the control panel.
User: enter user name exactly as it is written on the control panel.
PIN: enter user pin
Control Panel Operations: select User Management → Enable direct management over APP → Enable notification management over APP
Setting the App on the Smartphone: it needs to start the procedure of first association of the APP for every smartphone that uses the APP. During this operation it is necessary to
confirm it on the telephone when demanded: a sonorous signal will be hear at the end, and the phonename will be showed on panel. Into the User page each SmartPhones will be
showed: it is possible to change the name and to cancel the phone, blocking all functions and the consequent pushes info.
7.4.2) App SILENYA ADV SMS : free App for Android only; local & remote use by GPRS network (the GSM module is requested). This App can Arm/Disarm the panel and
verify/control the Panel's relays and the RF domotic relays. To program the relays on the phone it is necessary to write on the form showed in the phone the exact name assigned
to each device.
7.5) Setting up Email E-mail transmission of alarm event video frames as attachments. Both installer and Master user are authorized to carry out this operation.
Enable email management: enable
SMTP IP: enter name of the SMTP mail server SMTP port: 25 is supplied and it can be changed if required
SSL/TLS: enter network security supplied by provider User: enter username supplied by provider
Password: enter your email pw From: enter a valid e-mail (Sender). You can create an e-mail address specifically for the control panel
Select OK to confirm.
Fill in fields as follows: transmission takes place using the GSM/GPRS module.
Caution! Transmission cost is specified in the GSM agreement.
Caution! When setting up the transmission of multiple photos, each frame will be attached to a single mail.
Enabling e-mail reception: each user must be enabled to received video frames (user management) as well as the other listed alerts. Enable each one according to requirements.
8) MESSAGES SENT TO CENTRAL MONITORING STATION - DIGITAL PROTOCOLS
Entering the menù "Other parameters of communication" the pages of planning are available for the alarm digital transmission to a monitoring station
CONTACT ID protocol: the panel allows connections to two different numbers, Contact ID 1 and 2. The events to be sent are settables in the "Notify through CONTACT ID 1 or 2" .
Compile all the fields required : at the end it is possible to test the right connection by Test menu.
SIA protocol: this protocol will be implemented in the next FW realise
9) Control panelsl model 7002 and 7003 without tactile display (black-box)
Not having visualization, these panels must be programmed and configured through a PC, tablet or smartphone connected to WiFi produced by the panel that will be Access Point
with address 192.168.100.1
During connection the same displays of the models 7001-7002 will appear on the used screen, therefore the installing/modifying operations will be exactly the same.
These panels have a frontal led only, that shows the following operational phases:
Lighting green: Disarmed
Green flashing: Disarmed during a black out
Green flashing 10 seconds after disarmimg: New event - look at memory historical events
Lighting orange: Power-on / Updating in progress / Maintenance
Flashing orange: Maintenance during a black out
Lighting red: Armed (it flashes for the whole time of exit)
Red flashing: Armed during a black out (it flashes after the whole time of exit)
9.1) WiFi fail for substitution or anomalies of the router (central program as Client) - to proceed as it follows:
- Cut-off the power (230V and battery) and to attend 1 minute
- Connect the (charged) battery: the panel will involve as Access Point for 5 minutes, allowing to vary the parameters by PC or tablet
- Departed 5 minutes the panel will return Client as previously in absence of variations, or it will assume the new introduced parameters
10) Tools
10.1) Save System: save the entire setup of the control panel by downloading it to a USB flash drive or to the download of the PC. USB’s lodging is located to the left of the display.
10.2) System reset: reboot your system in order to solve any issues, restore previously archived backups or to update software via USB flash drive. No setup data will be lost with
this operation..
10.3) FW Updating: Silentron continually works for inserting improvements and new functions on the Advanced panels: all the updatings firmwares are also usable on the already
installed panels and are available on the site www.silentron.com. The updating can be effected in two ways, always with control panel disarmed: