• Connecttheredleadtotheanodeandtheblackleadtothe 
cathodeofthediodeundertesting.
Note:
• Themeterwillshowapproximateforwardvoltagedropofthe
diode.
• Iftheleadconnectionsisreversed,only'1'willbedisplayed.
Continuity Testing
• ConnecttheblacktestleadtoCOMjackandtheredtoVΩmA
jack.
• Settherotaryswitchattherangeposition.
• Connecttestleadsacrosstwopointsofthecircuitunder
testing.
• Ifcontinuityexists(i.e.resistancelessthanabout50Ω),the
built-inbuzzerwillsound.
Note:
Iftheinputisanopencircuit,thefigure'1'willbedisplayed.
Measuring Capacitor
• ConnecttheblacktestleadtoCx-jackandtheredtoCx+jack.
• Settherotaryswitchatthedesired20uF/200nFrangeposition.
• Beforeinsertingcapacitorundermeasurementintocapacitance
testingsocketbesurethatthecapacitorhas
 beendischargedfully.
Measuring Battery
• Loadresistance 1.5vrange:36Ω
9Vrange:360Ω
12Vrange:450Ω
• The1.5Vbatteryisgoodwhenthedisplayismorethan33mA.
• The9Vbatteryisgoodwhenthedisplayismorethan18mA.
• The12Vbatteryisgoodwhenthedisplayismorethan14mA.
MAINTENANCE
• Beforeattemptingtoremovethebatterydoororopenthecase,
besurethattestleadshavebeendisconnectedfrom
measurementcircuittoavoidelectricshockhazard.
• Toavoidelectricalshock,removetestleadsfrommeasurement
circuitsbeforereplacingthefuse.Replacefusesonlywitha
specifiedrating:F-200mA/250Vfuse.
•Replacethetestleadsiftheleadisdamagedorexposedin
anyway.Onlyreplaceleadswiththesametypeand
specification.
• Useonlymoistfabricorasmallamountofdetergent,never
usechemicalsolutionsforcleaning.
• Donotusethemeterbeforethebackcoverisproperlyclosed
andscrewsecured.
• Uponanysignsofabnormality,stopoperationimmediatelyand
sendthemeterformaintenancebyaqualifiedtechnician.