EasyManua.ls Logo

SilverStone STRIDER PLATINUM SERIES User Manual

SilverStone STRIDER PLATINUM SERIES
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SST-ST1200-PTS
STRIDER PLATINUM SERIES
Compact design with a depth of 140mm for easy integration
High efficiency with 80 PLUS Platinum certification
100% modular cables
24/7 continuous power output with 40 operating temperature
Class-leading single +12V rail
Strict ±3% voltage regulation and low ripple & noise
Built-in silent & durable hybrid ceramic bearing (HYB) fan
FF122 magnetized fan filter included
SST-ST1000-PTS
The world’s smallest kilowatt-level ATX power supply
Question and Answer IconNeed help?

Do you have a question about the SilverStone STRIDER PLATINUM SERIES and is the answer not in the manual?

SilverStone STRIDER PLATINUM SERIES Specifications

General IconGeneral
BrandSilverStone
ModelSTRIDER PLATINUM SERIES
CategoryPower Supply
LanguageEnglish

Summary

1. AC INPUT

1.1 AC input requirements

Input voltage, current, and frequency requirements for continuous operation.

2. DC OUTPUT

2.1 DC voltage regulation

Specifies the voltage regulation for various DC outputs.

2.2 Load ranges

Defines the load ranges for 1000W and 1200W configurations.

2.3 Output Ripple

Details the ripple and noise specifications for DC outputs.

2.4 Overshoot

Specifies limits for overshoot on turn on or turn off.

2.5 Efficiency

Lists efficiency and power factor at different load levels.

2.6 Remote ON/OFF control

Explains the functionality of the remote ON/OFF control.

3.0 PROTECTION

3.1 Over current protection

Details current limits to prevent damage from overcurrent.

3.2 Over Temperature Protection

Describes protection against over-temperature conditions.

3.3 Over-power protection

Specifies shutdown when output power exceeds rated limits.

3.4 Under voltage protection

Defines shutdown behavior under undervoltage conditions.

3.5 Over voltage protection

Details over voltage sense and protection mechanisms.

4.0 TIMING

4.1 Signal timing drawing

Illustrates signal timing for main power connector signals.

4.2 Hold up time

Specifies the minimum hold-up time after power loss.

5. ENVIRONMENT

5.1 Operation

Specifies operating environmental conditions for the power supply.

5.2 Shipping and Storage

Details environmental conditions for shipping and storage.

5.3 Altitude

Lists altitude limits for operation and storage.

6. SAFETY

6.1 Underwriters Laboratory (UL) recognition

Mentions UL recognition and compliance with UL 60950.

9. MECHANICAL REQUIREMENTS

9.1 Physical dimension

States the physical dimensions of the power supply.

10. POWER SUPPLY CONNECTOR OVERUSE DEFINITION

EN. Power supply connector overuse definition

Defines warranty limitations for connector overuse.

Related product manuals