Efficiency Rating | 80 Plus Titanium |
---|---|
Form Factor | ATX |
Fan Bearing | Fluid Dynamic Bearing (FDB) |
Power Good Signal | 100-500 ms |
MTBF | 100, 000 hours |
Series | STRIDER TITANIUM |
Type | ATX |
Modular | Fully Modular |
Dimensions | 150 mm (W) x 86 mm (H) |
Input Frequency | 47Hz ~ 63Hz |
Operating Temperature | 0°C ~ 50°C |
Protections | Over Power Protection, Over Voltage Protection, Short Circuit Protection, Over Temperature Protection, Under Voltage Protection, Over Current Protection |
Connectors | 1 x 24-Pin motherboard connector, 1 x 8-Pin EPS / ATX 12V connector, 6 x 8 / 6-Pin PCIe connector, 8 x SATA connector, 1 x Floppy connector |
Compliance | ATX12V v2.4 |
Input Voltage | 90 ~ 264 Vrms |
Input Current | 10A-5A |
Hold-up Time | ≥16ms |
Efficiency | 90% ~ 94% at 20% ~ 100% loading |
Details input voltage, current, and frequency for continuous operation.
Specifies voltage regulation for various DC outputs.
Defines load ranges for ST60F-TI, ST70F-TI, and ST80F-TI models.
Sets ripple and noise limits for DC outputs.
Defines overshoot limits during power transitions.
Details efficiency at different load levels and voltages.
Explains the function of the remote ON/OFF control signal.
Specifies over current limits and shutdown behavior for models.
Describes over-temperature protection and auto-recovery.
Defines shutdown behavior for over-power conditions.
Details under-voltage protection and shutdown.
Specifies over-voltage protection limits and behavior.
Defines short circuit protection for various outputs.
Describes power supply behavior during no-load operation.
Illustrates timing for main power connector signals.
Specifies hold-up time for regulation during power loss.
Specifies operating temperature and humidity.
Defines conditions for shipping and storage.
Specifies maximum operating and storage altitudes.
Mentions compliance with UL 60950 safety standards.
Specifies ESD immunity requirements according to IEC 61000-4-2.
Specifies EFT/B immunity requirements according to IEC 61000-4-4.
Specifies surge immunity requirements according to IEC 61000-4-5.
Specifies magnetic field immunity requirements according to IEC 61000-4-8.
Specifies voltage dips immunity requirements according to IEC 61000-4-11.
Specifies radiated susceptibility requirements according to IEC 61000-4-3.
Specifies conducted susceptibility requirements according to IEC 61000-4-6.
Specifies voltage fluctuation limits according to EN 61000-3-3.
Details harmonic current emissions compliance per EN61000-3-2.
Specifies Class B radio interference limits per EN55022/CISPR 22.
Specifies FCC Part 15 and ICE-003 compliance for operation.
Explains MTBF calculation methodology and demonstrated value.
Provides the physical dimensions (W x H x D) of the power supply unit.