IONIZATION SOLUTIONS
Extended Coverage
Ionizing Blower
Aerostat
®
XC2
User’s Manual

Other manuals for Simco-Ion Aerostat XC2

Questions and Answers

  • B
    Brittany BrewerAug 3, 2025
    What to do if my Simco-Ion Blower fan unit does not operate?
    • A
      Alexandra LopezAug 3, 2025
      If the Simco-Ion Blower fan unit isn't working, start by inspecting the power cords and connections to ensure they are properly connected. Also, examine the fan guards for any obstructions that may be preventing the fan from spinning.
  • H
    Howard HopkinsAug 8, 2025
    Why decay times are too long for Simco-Ion Aerostat XC2?
    • K
      Kelly LuceroAug 9, 2025
      If the decay times for your Simco-Ion Blower are too long, it might be due to dirty emitter points. Try cleaning the emitter points to resolve this issue.
  • S
    Sherry KingAug 14, 2025
    What to do if the fault alarm blinks intermittently on Simco-Ion Aerostat XC2?
    • C
      Christine WilsonAug 14, 2025
      If the fault alarm on your Simco-Ion Blower is blinking intermittently, the emitter points may be dirty. Cleaning them might solve the problem.
  • J
    jessica61Aug 20, 2025
    How to fix offset balance if it is more than 10V on Simco-Ion Blower?
    • N
      nicholas57Aug 20, 2025
      If the offset balance is greater than 10V on your Simco-Ion Blower, the emitter points may be dirty. Cleaning the emitter points should help.
  • S
    Sherri RiveraAug 27, 2025
    What does it mean if the FAN alarm is continuously ON on Simco-Ion Aerostat XC2?
    • L
      lisa80Aug 27, 2025
      If the FAN alarm is continuously ON for your Simco-Ion Blower, this indicates the fan has stopped. Check the fan guards for any obstructions that may be preventing the fan from operating.

Summary

Important Safety Information

Description

Performance Specifications

Outlines the static discharge times, balance specifications, and coverage area performance of the Aerostat XC2.

Installation and Setup

Unit Mounting and Positioning

Guides on how to properly mount and position the Aerostat XC2 for optimal performance and safety.

Electrical Connection Guide

Provides instructions on how to safely connect the Aerostat XC2 to a power source, including grounding.

Operation

Alarm Indicators

Details the FAN and FAULT LED alarms, their causes, and how to interpret them for troubleshooting.

Maintenance

Emitter Maintenance

Instructions for inspecting and cleaning the emitter cartridge, including removal and replacement procedures.

Troubleshooting Guide

Provides a table of common problems, possible causes, and solutions for the Aerostat XC2, including fuse replacement.

Warranty & Service

Simco-Ion Aerostat XC2 Specifications

General IconGeneral
Ionization MethodSteady-state DC
Frequency50/60 Hz
TypeBlower
Input Voltage120 VAC
AirflowAdjustable
Air VelocityAdjustable
Noise Level52 dB(A)