Table 2 Common Failures
Failure Description
Reason
Solution
The appliance does
not work.
1. Power failure.
2. Power cord is loose.
3. Control power fuse isbroken.
1. Turn off the power switch and
check the power.
2. Find out the problem and fix it.
3. Replace the fuse.
The appliance has
low heating capacity.
1. Refrigerant isinsufficient.
2. Water pipe's thermal
insulation performance is poor.
3. Dry filter is clogging.
4. The heat exchanger withair
has poor cooling.
1. Check if there is leakage andnote
the standard quantity ofrefrigerant.
2. Strengthen watersystem
insulation function.
3. Replace the dry filter.
4. Clean heat exchangerwith air.
The compressor
does not work.
1. Power supply or thecontroller
is broken.
2. The compressor'scontactor
fails.
3. The wire is loose.
4. The compressor'soverheating
protection works.
1. Find out the reason and solveit
accordingly.
2. Replace thecontractor.
3. Find out the loose point and fix it.
4. Identify the reason of overheating and
then turn on the appliance after trouble
shooting.
The compressor
works noisily.
1. Internal components are
damaged.
2. Frozen oil is not enough.
1. Replace thecompressor.
2. Add enough frozen oil.
The fan does
not work.
1. The capacitor isbroken.
2. The screw is loose.
3. The motor is broken.
1. Replace thecapacitor.
2. Tighten the screw.
3. Replace themotor.
The appliance does not
produce heat, while
the compressor is
working.
1. Refrigerant spreads out totally.
2. The compressor isbroken.
1. Check if there is leakage and fulfill the
standard quantity ofrefrigerant.
2. Replace thecompressor.
Discharge pressure is
too high.
1. Refrigerant is too much.
2. Fluorine-way systemcontains
non-condensable gas.
1. Expel excessiverefrigerant.
2. Exclude non-condensable gas.
Suction pressure is
too low.
1. Dry filter is blocked.
2. Refrigerant is toolittle.
1. Replace the dryfilter.
2. Check if there is leakage and fixit.
Non-Unit
Failure
1) There is water flow out of the drainage outlet of the safety valve:
When producing hot water, the cold water within the appliance is heated and expands,
so there is water flow out of the drainage outlet of the drain valve, which is normal case.
However, if there is water extruding continuously, that means the safety valve loses efficacy.
You should stop using the appliance and replace the safety valve as soon as possible.
2) The duration for heating a whole tank’s water becomes longer:
When the temperature is quite low in winter (e.g. 0), the heat pump’s performance
of producing hot water will not be as good as usual, so the duration for heating a whole
tank’s water becomes longer.
ATTENTION
If the appliance remains abnormal after you check as above, please contact the local service center
or dealer to send servicemen to repair the appliance promptly. Try to avoid the fuse fusing orthe
leakage protector turning on and off back and forth.