Sime FORMAT DGT Series - 3.8 Fumes Thermostat Safety; 3.9 Fumes Pressure Switch

Sime FORMAT DGT Series
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
with aspiration and discharge pipes of the
maximum length allowed.
The value of the signal to the pressure swit-
ch is measured by a differential pressure
gauge connected as indicated in fig. 16.
3.10 HEAD AVAILABLE
TO SYSTEM (fig. 17 - fig. 17/a)
Residual head for the heating system is
shown as a function of rate of flow in the
graph in fig. 17.
To obt ain the maximum head available to
the system, turn off the by-pass by turning
the union to the vertical position (fig. 17/a).
NOTE: The expansion vessel supplied with
the boiler is suitable for heating systems
with a maximum water capacity of 80
litres. In excess of such capacity, arrange
for an additional expansion vessel.
3.11 WATER PRESSURE
VALVE (fig. 17/a)
The water pressure valve (C fig. 17/a)
intervenes, blocking burner functioning, if it
detects that there is insufficient pressure
in the boiler (< 0,6 bar).
To restore burner functioning, to bring back
the pressure of the boiler at values compri-
se between 1 - 1,2 bar.
0
200
1600
140012001000800600400
PORTATA (l/h)
PREVALENZA RESIDUA (mbar)
500
400
100
200
300
Format DGT
600
By-pass inserito
By-pass escluso
83
ES
PT
ENG
RESIDUAL HEAD (mbar)
FLOW RATE (l/h)
PRESSOSTATO
VENTILATORE
CAMERA STAGNA
(+)
(--)
Fig. 16
Fig. 17
A
B
C
RIFERIMENTO POSIZIONE BY-PASS
Fig. 17/a
LEGENDA
A By-pass on
B By-pass off
CWater pressure valve
By-pass on
By-pass off
SEALED CHAMBER
FAN
PRESSURE SWITCH
REFERENCE POSITION BY-PASS