WARNING: The reeds should not and cannot be turned (diagram 4)
TEMPERATURE
The SIMONINI 250 has been designed to work under certain operating temperatures: so
please stick strictly as written.
Temperatures that must not be exceeded when cruising or when the engine is at a fixed
rpm for a long time:
• Exhaust gas temperature 58C.
• Temperature under spark plug 170° C.
Temperatures that must not be exceeded when taking off or when all the power is
required to the engine:
• Exhaust gas temperature 600° C.
• Temperature under spark plug 200° C.
WARNING engine will NEVER, at any time and condition, exceed:
• 600 ° C temperature of the exhaust gas.
• 200 ° C temperature under spark plug
It therefore makes it appropriate to adopt an instrument that detects these temperatures
for the protection of the engine, but especially for your and others' safety.
We also inform you that high exhaust gas temperatures, in many cases, are a symptom
of poor carburetion. While high temperatures under the spark plugs, usually, are due to
poor ventilation (heat dissipation) of the engine, caused by the presence of bodies and
/ or materials that prevent the passage of air cooling

Other manuals for SIMONINI MINI 2 EVO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIMONINI MINI 2 EVO and is the answer not in the manual?

SIMONINI MINI 2 EVO Specifications

General IconGeneral
BrandSIMONINI
ModelMINI 2 EVO
CategoryEngine
LanguageEnglish

Related product manuals