Simrad HS50 Heading Sensor
30 20221081 / F
Expert setup
By pressing the SETUP button twice and then holding this button
for 5 seconds, an Expert Setup category will be available in the
SETUP menu.
Use the rotary knob to enter the SETUP Expert submenu.
The following settings are available:
Head offset: Used for correcting a constant heading offset.
Refer Heading offset, page 31.
Alarm sound: Used for turning alarm text and alarm sound
on and off. Refer Alarms, page 39.
The following selections are available:
POS-Q
Only invalid position will activate alarm.
HDT-Q
Only invalid heading will activate alarm.
HDT-Q is the default setting.
All
Both invalid position and invalid heading will
give alarm.
Off
Used for tuning off all alarm text or alarm
sound.