EasyManua.ls Logo

Sinclair ASC-18A - Page 132

Sinclair ASC-18A
264 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
Sensor connection protection
E5 displayed
on wired
controller
Monitor displa
y
Mainboard indicato
r
Driver board indicato
r
Sensor
connection
p
rotection
Blink Bright
Bright Blink
Blink Bright
Bright Bright
Blink
If the compressor cable
U, V and W is
connected correctly?
If the U-phase compressor
cable is inserted through
U-phase current sensor
and if the V-phase
compressor cable is
inserted through V-phase
current sensor
If the compressor
winding is short
circuited, or open
circuited to ground
If IPM module is damaged
Replace the driver
board
Replace relevant
components
Record and feed
back
Yes
No
Yes
Yes
Yes
No
No
No