DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
125
Radiator overheat protection
E5 displayed on
wired controller
Monitor displa
y
Mainboard indicato
r
Driver board indicato
r
Radiator
overheat
protection
Blink Bright
Bright Bright
Blink Bright
Blink Dark
Blink
If the outdoor unit is in
good radiation?
If the air outlet and return air
inlet of the outdoor unit is short
circuited, it will cause the
radiating effect to become
poor.
I
f
the radiator is dirty or
blocked?
If the radiator is dirty or
blocked, it will cause the
radiating effect to become
poor.
Check if the radiator sensor is
failed or properly inserted
Record and feed
back
Yes
No
No