4.2. CONTROLLER
LED
Celsius degree
Fahrenheit degree
Minutes
On / Stand-by
Conservation
Time blast chilling / freezing
Temperature blast chilling / freezing
Defrost
Blast chilling hard / freezing
Freezing
Blast chilling
H.A.C.C.P.
Pre-cooling
BUTTON
On / Off
Start / Stop
Defrost
Increase
Menu
Decrease
Pre-cooling
Blast chilling
Freezing
Hard
4.2.1. SWITCHING ON AND OFF OF THE BLAST CHILLER
Press the button for one second, the led will light up or go off.
4.2.2. FUNCTIONING
After having switched the unit on with the button (see point 4.2.1) start the selected cycle as follows:
4.2.2.1. TEMPERATURE BLAST CHILLING SOFT WITH CORE PROBE (1) + CONSERVATION
4.2.2.2. TIME BLAST CHILLING SOFT (5) + CONSERVATION
Press and release the button
the led
will start flashing, the display will show the temperature of end cycle, which can be modified
with the buttons and (the value +3.0 is recommended).
Press and release the button
, the led and
will be steadily lighted and the working cycle including the conservation phase
will start. The check for the correct introduction of the core probe will be activated. If this test is successfully executed
, t
he cycle will go on in
temperature mode
(1); if the test is not successfully executed, the cycle will go on as time cycle in mode (5), the led
will go off and the
led will switch on.
At this point, within 5 minutes, press the button or to change the duration of the cycle in execution.
Keep the button pressed to interrupt the cycle.
Press the button to stop the conservation phase.