I
Sinexcel Ultra Static Var Generator (SVG)
--USER MANUAL
Sinexcel Electric Co., Ltd

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sinexcel SVG 100 Ultra and is the answer not in the manual?

Summary

Product Description

Product Introduction

Explains the function of SVG in improving power factor in electrical systems.

Product Features

Highlights modular design, adaptability, accuracy, user-friendly interface, and compact size.

Working Principle

Explains the device's function to eliminate reactive power in electrical systems.

Product Details Overview

220 V SVG Module Drawings

Details appearance and size of 220V SVG modules for wall and rack mounting.

400 V SVG Module Drawings

Module Wiring Terminals

Cabinet Solutions Overview

Flexible Cabinet Specifications

Top-Vent Cabinet Specifications

IP54 Cabinet Specifications

Installation and Wiring Guide

Pre-Installation Safety Notices

Provides CAUTIONary notes on installation, assembly, and power-on by qualified personnel.

Environmental Installation Requirements

Details requirements for ambient temperature, dust, magnetic fields, and humidity.

Installation Procedures

Wall-Mount Installation Guidelines

Provides NOTICE on clearance and mounting screw specifications for wall-mount modules.

Rack-Mount Installation Guidelines

Cabinet Installation Procedures

Flexible Cabinet Installation Details

Explains handling facilities for flexible cabinets and their installation clearances.

Top-Vent Cabinet Installation Details

IP54 Cabinet Installation Details

Module Connection Procedures

Single Wall-Mount Module Connection

Illustrates installation steps for power cables, CT, and HMI connection for single wall-mount modules.

Multiple Wall-Mount Module Connection

Single Rack-Mount Module Connection

Multiple Rack-Mount Module Connection

Cabinet Module Connection

Cable Management and Connections

Power Cable Guidelines

Provides CAUTION regarding power cable connection for 3P3W and 3P4W systems.

CT Cable Connection Procedures

Provides CAUTION and NOTICE regarding CT cable connection, including polarity and connection methods.

Single Module CT Connection Diagrams

Multiple Modules CT Connection Diagrams

Cabinet CT Connection Details

Communication Interface Connections

7-Inch HMI Communication Setup

Describes the 7-inch HMI for centralized control and monitoring of Sinexcel modules.

RS485 Communication Cable Usage

Provides NOTICE on connecting communication cables for parallel rack-mounted modules.

CAN Communication Cable Usage

DIP Switch Module Addressing

Commissioning Procedures

4.3-Inch HMI Overview

Introduces the 4.3-inch HMI for Sinexcel Ultra wall-mounted modules.

HMI Data Interface Navigation

HMI Waveform Visualization

HMI Spectrum Analysis

HMI Compensated Current Monitoring

HMI Power Analysis Display

HMI IO & Temperature Monitoring

HMI Debugging Parameters

HMI Version Information

CT Wiring Check Functionality

General Parameter Settings Introduction

Phase Angle Offset Settings

Target Voltage Control

External Passive Filter Setup

PT Ratio Configuration

THDU Limit Settings

Unbalanced Limit Settings

Derating Coefficient Settings

HMI Data Record Overview

Commissioning Steps (4.3-Inch HMI)

DC Bus Voltage Check Procedure

Explains the importance of DC bus voltage for judging component status and expected values.

HMI Data Verification with External Meter

Parameter Setup (4.3-Inch HMI)

7-Inch HMI Overview

HMI Info Interface Details

HMI Power Monitoring

HMI Waveform Visualization

HMI IO & Temperature Monitoring

HMI Data Record Overview

General Settings Parameter Introduction

CT Location Settings

Temperature Derating Configuration

Constant Reactive Power Settings

RP Tracking Control Value Settings

Parameter Setup (7-Inch HMI)

HMI Help Information

HMI About Information

SVG Specifications Overview

Human-Machine Interface Details

7-Inch HMI Dimensions and Structure

Presents dimensions and structure of the Sinexcel 7-inch HMI.

7-Inch HMI Data Recording and Download

HMI Records Download Function

HMI Data Record and Export Function

HMI Data Recording Procedure

HMI USB Data Export Procedure

HMI Power Saving and Holiday Functions

7-Inch HMI Advanced Parameter Settings

Target Voltage and Grid Adjustment

Voltage and Frequency Settings

PLL and Passive Filter Configuration

Transformer and Current Settings

LVRT and Expiry Day Settings

CT Connection and Configuration

Energy Saving and Fan Settings

Network and Model Configuration

THDU Limit and Unbalanced Limit Settings

Derating Factor and Test Mode Settings

Marine Filter and Over Temperature Protection

Controller Algorithm and Voltage Limits

Voltage Lower Limit and Phase Angle Bias

4.3-Inch HMI Advanced Parameter Settings

Network and Voltage Class Configuration

Explains setting module network structure and actual rate voltage.

RP Tracking and Over Temperature Settings

Explains reactive power tracking and over-temperature alarm settings.

Advanced Parameter Configurations

Transformer and Impedance Settings

Control Bandwidth and Oscilloscope Settings

Current Calibration Settings

Inverter and Voltage Calibration Procedures

Frequency, PLL, and Current Abnormality Handling

Transformer Type and Expiry Day Settings

LVRT and CT Ratio Settings

Fan Gear and Grid THDU Calibration

Grid THDI and Load THDI Calibration

Product Model and Alarm Clearing

7-Inch HMI Software Upgrade Instructions

4.3-Inch HMI Software Upgrade Instructions

J-Link Driver Check and Setup

CPU Device and Target Interface Selection

Connecting to J-Link for Upgrade

Programming Hex File and Upgrade Completion

SD Card Preparation and Folder Copying

SD Card Insertion and Module Power Off

HMI Software Update Execution

SVG Module Factory Calibration

Calibration Preparations and Settings

Outlines necessary preparations and initial settings for the calibration process.

Input Voltage Configuration Procedure

CT and Inverter Current Configuration

Inductor Current Configuration Procedure

Appendix III Dry Contact Board Introduction

Dry Contact Board Interface and Dimensions

Introduces the Dry Contact Board, its interface, dimensions, and structure.

RJ45 Ethernet Port Functionality

Dry Contact Output 2 Functionality

Dry Contact Output 1 Functionality

Input Dry Contact Functionality

Dry Contact Board Installation Position

Connecting Dry Contact Board to LCD Module

Connecting Dry Contact Board to 7-Inch HMI

Appendix IV Modbus Protocol Guide

Modbus Data Verification and Function Codes

Modbus Function Code 02: Status;Alarm

Modbus Function Codes 03;04: Analog Data

Modbus Function Code 16: Parameter Setting

Modbus Error Codes and Faults

Acquiring Device Status and Alarm Information

Acquiring Analog Data via Modbus

Reading Waveform Data (Waveform)

Reading Waveform Data (Histogram)

Acquiring Manufacturer Information

Reading Monitor Manufacturer Information

Acquiring General Device Parameters

Acquiring Phase Angle Offset Parameters

Acquiring Harmonic Compensation Parameters

Acquiring Device Parameters (No Initialization)

Reading Harmonic Compensation Modes

Setting Device Parameters Overview

Sinexcel Modbus Application Overview

Modbus TCP;IP Connection Methods

Details connection methods for Modbus TCP/IP, including PC to monitor direct connection.

Modbus TCP;IP Via Router Connection

Modbus RTU Communication

Appendix IV ICMS-P2 Integrated Control System

ICMS-P2 Interface and Dimensions

Provides interface details and dimensions for the ICMS-P2.

ICMS-P2 Introduction and Overview

ICMS-P2 Functional Characteristics

ICMS-P2 Service Environment

ICMS-P2 Definition and Functionality

ICMS-P2 Real-Time Data Monitoring

ICMS-P2 Waveform Display

ICMS-P2 Historical Data Analysis

ICMS-P2 Data Management

ICMS-P2 Technical Parameters

ICMS-P2 Basic Parameters

Details the maximum power consumption and output nodes of the ICMS-P2.

ICMS-P2 Measurement Accuracy

Lists the accuracy values for voltage, current, frequency, and power measurements.

ICMS-P2 Control and Protection Parameters

ICMS-P2 External Communication Interfaces

Appendix VII Cabinet Designing Instructions

Cabinet Component List for Design

Lists components required for designing cabinets.

Cabinet Ventilation Design Guidelines

Details requirements for cabinet ventilation design, focusing on air cooling.

Fan-Forced Air Cooling Design

Appendix VIII Current Transformer (CT) Information

Current Transformer Types

Describes different types of CTs and their suitability.

Current Transformer Cable Specifications

Details the specifications and connection of CT cables.

CT Secondary Side Connection

Explains how to connect secondary CT cables to the SVG module.

Current Transformer Sizing Guidelines

Provides guidance on selecting the CT ratio based on load current.

CT VA Burden and Selection

CT Instruction and Function

Explains the function of current transformers for measuring current.

CT Mechanical Structure Types

Describes the two main types of CTs: solid-core and split-core.

CT Ratio Compatibility

States Sinexcel SVG compatibility with CTs having secondary side current of 1A or 5A.

CT Burden Definition

Defines CT burden as total secondary side resistance and its common expressions.

CT Cable Length Considerations

Discusses factors to consider when choosing CT cable length and resistance.

CT Cable Impedance Calculation and Conclusion

SVG Module VA Burden Calculation

CT Special Application Installation Advice

Appendix VIII Cable Sizing Recommendations

Appendix IX System Power On and Shutdown Procedures

Power On Sequence Steps

Provides step-by-step instructions for powering on the SVG system.

Power Off Sequence Steps

Provides instructions for safely powering off the SVG system and conducting safety checks.

Automatic Power On Functionality

Explains conditions and settings for automatic SVG power-on after utility power recovery.

Emergency Stop Procedure

Describes how to use the EPO button to perform an emergency shutdown and subsequent restart.

Appendix XI Common Fault Diagnosis and Solutions