TELEFRANG AB
SIOX Modem Expander R40
General Description
R40 is an interface unit be-
tween a GSM modem and
several serial devices using
RS232, RS485 and a SIOX
bus. It is powered from mains
or a DC supply, 10..48 V.
In addition, it includes 2 ana-
log inputs which also may be
used for alarms etc. Its en-
hanced PLC programmability
permits it to work standalone,
as a protocol converter or as
the multiplexer for a modem.
Versions: R40-3, 12V powered SIOX Modem Expander.
Order number: 6R40-3
R40-4, Mains powered SIOX Modem Expander.
Order number: 6R40-4
R40-5, 24V powered SIOX Modem Expander with power Relay.
Order number: 6R40-5
R40man.wpd/090513/TF
R40 MODEM EXPANDER MODULE p 2
Contents
General Description .......................................1
Versions .................................................1
Power Supply ............................................3
Installation and Start-Up ...................................3
Terminal Blocks ..........................................4
SIOX Address Setup .......................................5
RS485 Soft Handshaking ...................................5
Ports’ Multiplexing ........................................6
Modem ..................................................7
Modem-to-SIOX LINK Mode .................................7
Modem-to-Serial LINK Mode ................................8
SIOX Text-to-Serial LINK Mode ..............................8
PLC .....................................................8
Digital/Analog Inputs ......................................9
Power Relay .............................................9
SIOX Message Transfer for R40 .............................9
Parameter Setup .........................................11
Safety Precautions .......................................17
Electrical Specifications ..................................18
Environmental Specifications ..............................18
Mechanical Specifications .................................18
Question and Answer IconNeed help?

Do you have a question about the SIOX TELEFRANG R40 Series and is the answer not in the manual?

SIOX TELEFRANG R40 Series Specifications

General IconGeneral
BrandSIOX
ModelTELEFRANG R40 Series
CategoryRecording Equipment
LanguageEnglish

Summary

General Description

Power Supply

Installation and Start-Up

SIOX Address Setup

Modem

Modem-to-SIOX LINK Mode

Copies characters between the GSM modem and the SIOX bus for direct communication.

Modem-to-Serial LINK Mode

Links serial buffers with modem buffers for data transfer independent of speed/format.

SIOX Text-to-Serial LINK Mode

Allows SIOX Text messages to operate directly on serial port buffers, bypassing the modem.

PLC

Digital/Analog Inputs

Parameter Setup

Parameter 00: Soft Reset

Copies EEPROM to RAM for a full soft reset, using previous EEPROM value.

Parameter 01: Serial Errors

Allows buffering of received characters with incorrect parity or bits.

Parameter 04: Link Modes

Configures modem reset, data carrier detect, send requests, and buffer flushing.

Parameter Setup (Continued)

Parameter 04: Link Modes (Cont.)

Configures SIOX Link to Modem, Link No Echo, and SIOX Break indications.

Parameter 12: PLC Timer Tick

Sets PLC timer tick frequency for timing operations.

Parameter 05: RS485 Status & Mode

Sets RS485 status, data bits, stop bits, parity, and bit rate.

Parameters 06-07: RS232 Mode

Configures RS232 hardware status, data bits, stop bits, parity, and bit rate.

Parameter 10: DO Register

Controls PLC bits Q8-Q1 for SIOX code reception and relay control.

Parameter 11: DI Register

Provides DI register for PLC bits and digital inputs status.

Safety Precautions