Operating Instructions
SKC Inc.
863 Valley View Road
Eighty Four, PA 15330 USA
Form 37740 Rev 1707
Question and Answer IconNeed help?

Do you have a question about the SKC AIRCHEK 2000 and is the answer not in the manual?

Summary

Product Description

Performance Profile

Battery Operation

Installing the Battery Pack

Guide for properly installing the battery pack into the pump base.

Charging the Battery Pack

Instructions for charging the battery pack using the charger.

Battery Charge Level Indicator

Explanation of battery status icons and low battery fault indication.

Replacing the Battery Pack

Procedure for removing and replacing the battery pack.

Battery Eliminator

Details on using the battery eliminator for extended operation.

Introduction

Pump Display

Explanation of AirChek 2000 LCD display elements and icons.

Keypad Basics

Overview of the pump keypad buttons and their functions.

Pump Operating Modes

Description of RUN, HOLD, SLEEP, and Flow Fault modes.

Setup

Verifying Battery Charge Level

How to check the current battery charge level on the pump's LCD.

Entering and Navigating the User Interface

Guide to accessing and using the pump's two-level user interface.

Using User Interface - Level One

Instructions for setting and calibrating flow rate using Level One.

Using User Interface - Level Two

Instructions for setting sampling and display parameters using Level Two.

Resetting Run Time Data

Procedure to reset accumulated volume and run time data to zero.

Setting Pump Flow Rate

Steps to set the desired flow rate for the pump.

Setting Sample Time (ST)

How to program the sampling time for STEL, TWA, or other run times.

Setting a Delayed Start

Instructions for setting a delayed start for sampling operations.

Deleting a Sample Time (ST)

Procedure to clear a previously set sample time.

Deleting a DataTrac 2000 Program

Method to remove a DataTrac 2000 program from pump memory.

Operation

Flow Rate and Volume Display

Explanation of flow rate and volume display on the pump's LCD.

High Flow Applications (1000 to 3250 ml;min)

Instructions for setting and calibrating flow rate for high flow rates.

Set;Calibrate Flow Rate (Manual)

Manual procedure to set and calibrate the pump's flow rate.

Set;Calibrate Flow Rate (CalChek Single-point)

Using CalChek feature for single-point automatic flow rate calibration.

Set Up;Sample (Constant Flow)

Procedure for setting up and running a constant flow sample.

Low Flow Applications (5 to 500 ml;min)

Overview of low flow sampling requirements and accessories.

Set;Calibrate Flow Rate for Single Tube

Steps to set and calibrate flow rate for single tube low flow sampling.

Flow Rate Through Sorbent Tube

Procedure to adjust flow rate through the sorbent tube.

Set Up;Sample with Single Tube

Steps for setting up and running a single tube sample.

Set;Calibrate Flow Rate for Multiple Tubes

Instructions for setting and calibrating flow rate for multiple tubes.

Flow Rate Through Sorbent Tubes

Procedure for adjusting flow rate through multiple sorbent tubes.

Set Up;Sample with Multiple Tubes

Steps for setting up and running a multiple tube sample.

Maintenance

Replacing the Inlet Port Housing and Filter

Procedure for replacing the pump's inlet port housing and filter.

Full Calibration (CalChek Multiple-point)

Procedure for performing a full, multi-point calibration using CalChek.

Troubleshooting

CalChek Error Chart

List of CalChek calibration errors and their troubleshooting steps.

Replacement Parts

Accessories

DataTrac 2000 Software

Details on the DataTrac 2000 software for programming and data management.

Warranty

SKC AIRCHEK 2000 Specifications