BA-µflowQAL-en-L-1740.docx
µFLOW 100LSE-QAL
compact calculator for
gas applications
Instruction manual
Valid from software version LSE-QAL-211

Questions and Answers

  • P
    Patricia BarnesAug 8, 2025
    Why is there no display indication on my SKI Test Equipment?
    • T
      teresajamesAug 8, 2025
      The lack of display indication on your SKI Test Equipment might be due to a missing auxiliary power supply. Check the auxiliary power supply to resolve this. Alternatively, the main fuse could be defective. In that case, replace the main fuse.
  • M
    morganjordanAug 12, 2025
    What to do if auxiliary power for sensors is missing in SKI uFLOW 100LSE-QAL?
    • L
      Laura AndrewsAug 12, 2025
      If auxiliary power is missing for the sensors in your SKI Test Equipment, the fuse for 24VDC may be defective. Replace the fuse for 24VDC. Another possibility is an external short circuit. Check for any external short circuits.
  • J
    Jeffrey JonesAug 16, 2025
    Why are the indicated measured and calculated values not realistic on my SKI uFLOW 100LSE-QAL Test Equipment?
    • G
      Gina WestAug 16, 2025
      Unrealistic measured and calculated values on your SKI Test Equipment could be due to wrong parameter configuration. Reconfigure the parameters to correct this.
  • R
    Richard WalkerAug 21, 2025
    How to fix wrong output current on SKI Test Equipment?
    • M
      Michele RodgersAug 21, 2025
      A wrong output current on your SKI Test Equipment may be caused by an incorrect structure, such as 0..20 mA instead of 4..20 mA, or vice versa. Adjust the output current structure accordingly. It could also be due to a wrong zero or span value. Correct the zero or span value.
  • T
    Tonya TerryAug 26, 2025
    What to do if SKI uFLOW 100LSE-QAL Test Equipment does not react on the Pt100 input?
    • N
      Nathan HarrisAug 26, 2025
      If your SKI Test Equipment isn't reacting to the Pt100 input, it could be due to a wrongly chosen Sensorbyte. Select the correct Sensorbyte. Another potential cause is that the DIP-switches are in the wrong position. Correct the DIP-switch settings.
  • K
    Kaitlyn RomeroAug 29, 2025
    Why SKI uFLOW 100LSE-QAL does not react on the frequency input?
    • L
      Lynn ConleyAug 30, 2025
      If your SKI Test Equipment isn't reacting to the frequency input, it might be because the Sensorbyte was chosen incorrectly. Select the correct Sensorbyte. Also, the setting of the jumper might not fit the signal. Adjust the jumper setting.
  • S
    Susan MillerSep 2, 2025
    What to do if SKI Test Equipment does not react on the current inputs?
    • W
      William FisherSep 2, 2025
      If your SKI Test Equipment isn't reacting to the current inputs, it could be because the Sensorbyte was chosen incorrectly. Select the correct Sensorbyte.

SKI uFLOW 100LSE-QAL Specifications

General IconGeneral
BrandSKI
ModeluFLOW 100LSE-QAL
CategoryTest Equipment
LanguageEnglish