• Test Emergency Power
CAUTION
When operating on auxiliary power, do
not operate more than one function
at a time to avoid overloading 12-Volt
auxiliary pump motor. Do not use
emergency power unit continuously
for more than two minutes for models
SJ46AJ/SJ51AJ and for more than three
minutes for model SJ63AJ.
NOTE
To conserve battery power, test each
function through a partial cycle.
1. On platform control console, push in “ ”
emergency stop button to turn engine off.
2. Pull out “ ” emergency stop button.
3. Select “ ” on position from engine start/
on/off switch.
4. Depress and hold footswitch.
5. Turn “ ” emergency power switch to
“ ” on position and activate each function
control handle or switch.
Result: All boom and steer functions
should operate. Drive functions should
not operate.
NOTE
The emergency power unit has a
two-minute duty cycle for models SJ46AJ/
SJ51AJ and a three-minute duty cycle for
model SJ63AJ.
• Test Horn
1. Push “ ” horn pushbutton.
Result: Horn should sound.
149432AA149432AA
At Platform Controls:
1. Pull out emergency stop button.
2. Depress and hold foot switch.
3. Activate emergency pump switch.
4. Activate desired boom function.
EMERGENCY LOWERING
PROCEDURE
Drive/Steer
Controller
Horn
Engine Start/On/Off
Switch
Emergency
Stop
Section 2 - Familiarization Function Tests