26
4.) Ascender battery
SKYLOTEC Ascenders use specially designed lithium-based batteries with a very high energy density and are therefore very compact, light-weight and
extremely powerful. Due to the high energy the batteries contain, it is of utmost importance that they are treated with care and that the user has read the
following section with attention. This is for your own safety, but also for optimal Battery life and performance.
SKYLOTEC recommends users to follow the Battery care guidelines below for optimal lifetime and performance:
battery can stay connected to ACX during transport or short term storage (1 week). For longer storage, disconnect the Battery and do a
maintenance charge every 3 months
always charge batteries as soon as possible after use
disconnect batteries from the charger after charging
always store batteries fully charged
store batteries between 5°C (41°F) and 25°C (77°F)
WARNING: Not following instructions may result in damage to property, serious bodily injury or death.
NOTE: Under normal service conditions it is expected that the Battery will last 5 years. The lifetime is dependent on, how much load is lifted and the
operational temperatures (See also section 4.8).
General guidelines and warnings
Battery charging must be conducted in a safe area away from combustible or other ammable materials
Do not charge the Battery unattended
When hot, allow the Battery to cool down to room temperature before charging
Immediately remove the Battery
or charger from service:
- if there is visible damage to the housing, cables or connectors, including the battery connectors on the ascender
- if the battery has been dropped as there may be internal damage that isn’t visible
- if the battery emits an unusual smell, feels hot, produces smoke, changes shape, or appears abnormal in any other way. since a
delayed reaction can occur, observe the battery for a minimum of 15 minutes in a safe area and away from any combustible
material
Only use the original SKYLOTEC ACX Battery Charger