39
6.) Service & Maintenance
Only use original spare parts and materials recommended and supplied by SKYLOTEC Systems.
Basic Inspection Guidance for users and third party inspection:
To be used safely, each Ascender should meet following requirements at all times:
• no obvious damage or excessive wear on Ascender and its components
• basic function test of Ascender including Emergency Stop and emergency descent.
• 1,25 x SWL dynamic load test; descending full speed and then stop with max 10 cm (3,9”) slippage
• 1,5 x SWL static load test; no slippage allowed
NOTE: Go through ‘Checklist before use’ (5.10) during every maintenance!
6.1) maintenance & cleaning of the ascender
Repairs, annual service and inspection shall be carried out by an SKYLOTEC-authorised service partner. More frequent inspection intervals may be
required because of local regulations.
Cleaning the Ascender
• wipe the Ascender with a wet cloth and let it dry. Do not clean the Ascender with a high-pressure cleaner.
• clean the Carabiner thoroughly, lubricate with thin oil and wipe dry.
• spray the pins with an electronic connector cleaner/lubricator when needed.
WARNING: Do not use a high-pressure cleaner.
6.2) Trouble Shooting Guide
If you need further assistance or are in any doubt please contact SKYLOTEC Systems or your approved SKYLOTEC distributor.