CX Manual Flushometers
TROUBLESHOOTING GUIDE
1
2
Item No. Part No. Description
1 See Table Piston Assembly
2 See Table Activation Assembly
Code No. Description Plug Color*
3340048 1.6 gpf/6.0 Lpf closet activation assembly Green
3340049 1.28 gpf/4.8 Lpf closet activation assembly Purple
3340051 0.5 gpf/1.9 Lpf urinal activation assembly Red
3340052 0.25 gpf/1.0 Lpf urinal activation assembly Burgundy
ACTIVATION ASSEMBLY SELECTION GUIDE
* Colors may differ. Consult factory to conrm you have the correct piston assembly.
Item Code No. Description
1 0323182 V-651 Vacuum Breaker
2 0323279 Short Vacuum Breaker Tube
3 0306394 Adjustable Tube
4 0306395 Poly Washer Coupling (set of two)
5 0306392PK Elbow
6 3306002 1-1/2" Coupling with S-21 Gasket
7 0306031PO 1 1/2" (38 mm) Flanged outlet tube RB, 6"
8 0396669PK F-102 1-1/2" (38 mm) Outlet Tube CP 8"*
9 0306238PK F-7 Flange CP*
10 0306146PK F-5-A 1-1/2" Spud Coupling Assembly CP*
11 0306396 Urinal Connection
FLUSH CONNECTION PARTS
Plug
The information contained in this document is subject to change without notice.
Manufactured in the U.S.A by Sloan Valve Company under one
or more of the following patents: U.S. Patents. 5,295,655;
5,542,718; 5,558,120; 5,564,460; 5,730,415; 5,865,420;
5,887,848; 5,967,182. Other Patents Pending.
Bak-Chek
®
, Para-flo
®
, PERMEX
®
, Turbo-Flo
®
* Consult factory for alternate nish options
1
2
3
4
10
5
4
8
7
Install with
Flange against spud
For Model 158, Wall Hung
For Model 158, Floor Mount
9
4
For Model 198
11
Code No. Description Piston Color*
3340053 1.6 gpf/6.0 Lpf closet activation assembly Green
3340054 1.28 gpf/4.8 Lpf closet activation assembly Purple
3340055 0.5 gpf/1.9 Lpf urinal activation assembly Red
3340056 0.25 gpf/1.0 Lpf urinal activation assembly Burgundy
PISTON ASSEMBLY SELECTION GUIDE
Question and Answer IconNeed help?

Do you have a question about the Sloan CX and is the answer not in the manual?

Sloan CX Specifications

General IconGeneral
BrandSloan
ModelCX
CategoryMeasuring Instruments
LanguageEnglish

Summary

Troubleshooting Guide

Flushometer Not Functioning

Troubleshooting steps for when the flushometer does not operate or flush.

Insufficient Water Volume

Diagnosing and resolving issues with low water volume for effective bowl evacuation.

Flushometer Closes Immediately

Addressing the problem of the flushometer shutting off prematurely.

Short Flush Issues

Identifying causes and solutions for a flush cycle that is too brief.

Long or Continuous Flush

Troubleshooting prolonged or continuous flushing cycles.

Chattering Noise During Flush

Resolving audible chattering sounds during the flush operation.