Test Sensor by standing in front of Sensor for Ten (10) Seconds.
Step away from Sensor and listen for "CLICK."
Click
any questions
?
• We recommend that you review our G2 OPTIMA Plus Installation Instruction Manual and Maintenance Guides for
complete instructions including Rough-in Dimensions, Specifications, Troubleshooting Guide, and Replacement Parts.
• Call our Customer Service for additional information at 1-800-440-5556 or fax them at 1-503-643-844.
The information contained in this document is subject to change without notice.
Test your Flushometer!
AIR DELIGHTS, INC. • 9974 SW ARCTIC DR. • BEAVERTON, OR 97005
Phone: 1-800-440-5556 or 1-503-352-1201 • Fax: 1-503-643-8442 • www.airdelights.com
Copyright © 2003 Sloan Valve Company • Printed in the U.S.A. • Made in the U.S.A. • 0816455 — Rev. 0 (05/03)
9
16
13
15
17
11
12
Tighten with Strap Wrench. Pull Tab to activate.
Install Assembly onto
the Flushometer Valve
Body. Lens must face
directly forward.
8 10
Activate Flushometer and adjust Control Stop after each flush until rate of flow delivered
properly cleanses the fixture. The Control Stop should never be opened to the point
where the flow from the valve exceeds the flow capability of the fixture. In the event of a
valve failure, the fixture must be able to accommodate a continuous flow from the valve.
Open Control Stop (counterclockwise) ½ turn
from closed position.
Place hand over lens for 10 seconds
or press override button to activate.
Adjust Control Stop to meet the flow
rate requirement for proper cleansing
of the fixture.
Install Control Stop Cap.
14
Range adjustment is factory set
and typically does not require
adjustment.
If range adjustment is required,
refer to the Installation
Instructions furnished with the
G2 Optima Plus Flushometer.