30 - INSTALLATION 91477B145/A
The fuses blow or the circuit breaker of the
residential electrical system trips repeatedly.
• Call Technical Support or an electrician.
There are cracks or fissures in the hob:
• Turn off the appliance immediately,
disconnect the power supply and contact
Technical Support.
INSTALLATION
Electrical connection
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Power limitation menu
The following procedure can be used to adjust
the maximum power from 7.2 to 2.8 kW (high
power regime):
1. Switch off all the plates before proceeding.
2. Disconnect the appliance from the mains
power supply.
3. Reconnect the appliance to the mains power
supply.
Carry out the following procedure within 30
seconds of the appliance being reconnected:
4. Press and hold the button to unlock the
controls.
5. Press the and buttons at the same
time.
• A beep will be emitted and the current
power level will be shown on the display.
6. Use the and buttons to change the
value.
7. Press the and buttons at the same
time to save the new power value. The
appliance will switch off and you will have
See General safety instructions.
220-240 V 1N~
3 x 6 mm ²
three-core cable
380-415 V 2N~
4 x 2.5 mm ²
four-core cable
220-240 V 2~
3 x 6 mm ²
three-core cable
220-240 V 3~
4 x 2.5 mm ²
four-core cable
380-415 V 3N~
5 x 1.5 mm ²
five-core cable
The values indicated refer to the cross-
section of the internal conductor.
The aforementioned power cables are
sized taking into account the
coincidence factor (in compliance with
standard EN 60335-2-6).
• This function allows you to set the
maximum power limit for your
appliance.
• The appliance is factory set to a
maximum power of 7.2 kW, but
can be regulated to operate at
6.0, 3.5 and 2.8, 2.2, 1.6, and
1.0 kW.