Use
69
EN
Option U4 modifies the brightness of the
display. 10 levels can be selected.
• 0: maximum brightness.
• 9: minimum brightness.
Option U5 allows you to modify the type of
animation of the seconds countdown of the
independent timer and timed cooking, from
59 to 0 seconds.
• 0: animation 1.
• 1: animation 2.
Option U6 allows you to activate or
deactivate the automatic pan detection
function. (see “Switching on the cooking
zone automatically”).
• 0: automatic detection off.
• 1: automatic detection on.
Option U7 specifies the duration of the
alarm when the timer has ended. 3 levels
can be selected:
• 0: alarm duration 120 seconds.
• 1: alarm duration 10 seconds.
• 2: alarm disabled.
Option U8 allows you to activate the Auto-
Vent 2.0 function in automatic mode. 8
levels can be selected. The following table
summarises the possible settings:
Refer to the following table to choose the
most suitable setting level according to the
power limitation of the appliance:
Option U9 allows you to activate or
deactivate the Auto-Vent 2.0 function:
• 0: function off.
• 1: function on.
The seconds countdown is
displayed when the timer is set for
1 minute.
Setting
level
Hood
lighting
Hood fan speed
Delicate
cooking
Medium
cooking
Intense
cooking
0 off off
1 on off
2 - 4 - 6 on off speed 1 speed 2
3 - 5 - 7 on speed 1 speed 2 speed 3
Setting level Power limitation
2 - 3 up to 4 kW
4 - 5 from 4 to 5 kW
6 - 7 from 5 to 7.4 kW
If you select a higher power level
compared to the one that has
been set, it may not be possible to
select some of the hood fans
speeds.