    Natalie PerezAug 7, 2025
    Why is there insufficient suction in my Smeg SPUM90X Ventilation Hood?
    • C
      carlsonbrianAug 7, 2025
      If your Smeg Ventilation Hood exhibits insufficient suction, it might be due to the distance between the hood and the gas top being too long, in which case you should readjust the distance. Another possible cause is too much ventilation from open doors or windows. To resolve this, consider choosing a new location and reassembling the machine.
  • S
    simpsonjoyceAug 12, 2025
    What to do if my Smeg SPUM90X shakes?
    • F
      flewisAug 12, 2025
      If your Smeg Ventilation Hood's body is shaking, it could be due to several reasons. The leaf might be damaged, requiring a replacement. Alternatively, the motor might not be tightly secured, so ensure it is properly locked. Lastly, the body itself might not be tightly fixed, so ensure the body is tightly secured.
  • K
    Kevin AdamsAug 17, 2025
    How to fix a Smeg SPUM90X Ventilation Hood when the light is on but the motor doesn't work?
    • J
      Jennifer BaileyAug 17, 2025
      If the light on your Smeg Ventilation Hood is on, but the motor isn't working, there could be several reasons. A leaf might be blocking the motor, so you should remove the blockage. The capacitor could be damaged, necessitating a replacement. Alternatively, the motor bearing might be jammed or damaged, or there may be an internal issue causing the motor to shut off or emit a bad smell, in which case you should replace the motor.
  • V
    victoriahernandezAug 22, 2025
    Why is my Smeg SPUM90X Ventilation Hood inclining?
    • A
      Amber TranAug 22, 2025
      If your Smeg Ventilation Hood is inclining, the fixing or hanging screws may not be tight enough. Tighten the hanging screw to ensure the hood is horizontal.
  • B
    bryantnancyAug 27, 2025
    What to do if my Smeg SPUM90X Ventilation Hood has an oil leakage?
    • S
      stephanie34Aug 27, 2025
      If your Smeg Ventilation Hood experiences oil leakage, it could be due to the one-way valve and air ventilation entrance not being tightly sealed. In this case, take down the one-way valve and seal it with glue. Another possible cause is leakage from the connection of the U-shaped section and cover, so take the U-shaped section down and seal it with soap or paint.
  • B
    Bruce MartinezSep 1, 2025
    How to troubleshoot a Smeg SPUM90X when the light and motor don't work?
    • S
      Sydney SullivanSep 1, 2025
      If the light and motor on your Smeg Ventilation Hood don't work, the light may be damaged, requiring replacement. Additionally, the power cord might be loose, so connect the wires as per the electric diagram.

Summary

1. WARNING

2. INSTALLATION INSTRUCTIONS

Preparation

Steps for preparing the installation, including drilling holes and measuring.

Installation Method 1

Instructions for mounting the hood using screws and fixing it to the cabinet.

Installation Method 2

Steps for attaching the mounting bracket and securing the hood to the wall and cabinet sides.

Installation Method 3

Procedure for fixing the hood to the cabinet from the top using screws, washers, and nuts.

3. OPERATION

4. LIGHT REPLACEMENT

5. CHARCOAL FILTER INSTALLATION

6. MAINTENANCE

7. ATTENTION

8. TROUBLESHOOTING

Warranty Information and Registration

Warranty Conditions

Requirements and adherence for a valid warranty claim, including proper use and installation.

Warranty Exclusions

Specific situations and damages not covered by the manufacturer's warranty policy.

Other Product Warranty Periods

Warranty durations for different Smeg appliance categories like blenders and mixers.

Smeg SPUM90X Specifications

General IconGeneral
TypeWall-mounted
Width90 cm
Number of Speeds3
LightingLED
InstallationWall-mounted
Number of Lights2
MaterialStainless steel
Energy Efficiency ClassA
Number of Motors1
Filter TypeAluminum grease filter