Installation
82
The nozzles not provided are available at Authorised Service Centres.
8 Liquid Gas G30/31
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
50 65 85 46 + 91
Pre-chamber (printed on nozzle)
----
Reduced capacity (W)
400 500 800 1900
Rated capacity G30 (g/h)
73 131 211 305
Rated capacity G31 (g/h)
71 129 207 300
9 Liquid Gas G30/31
AUX SR R UR2
Rated heating capacity (kW)
1.1 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
50 62 81 46 + 85
Pre-chamber (printed on nozzle)
----
Reduced capacity (W)
450 550 800 1900
Rated capacity G30 (g/h)
80 131 211 305
Rated capacity G31 (g/h)
79 129 207 300
10 Liquid Gas G30/31
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
43 58 70 43 + 70
Pre-chamber (printed on nozzle)
(H2) (M) (Y) (H2) + (S1)
Reduced capacity (W)
400 500 850 1900
Rated capacity G30 (g/h)
73 131 211 305
Rated capacity G31 (g/h)
71 129 207 300
11 City Gas G110
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 2.8 3.8
Nozzle diameter (1/100 mm)
145 185 260 140 + 320
Pre-chamber (printed on nozzle)
(/8) (/2) (/3) -
Reduced capacity (W)
400 500 800 1400
12 City Gas G120
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 2.8 3.9
Nozzle diameter (1/100 mm)
135 175 240 130 + 290
Pre-chamber (printed on nozzle)
(/8) (/1) (/3) -
Reduced capacity (W)
400 500 800 1400