EasyManua.ls Logo

Smiths Medical Graseby C9 User Manual

Smiths Medical Graseby C9
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Find your local contact information at:
www.smiths-medical.com/customer-support/contact-us
Smiths Medical is part of the global technology business Smiths Group plc. Please see
the Instructions for Use/Operator’s Manual for a complete listing of the indications,
contraindications, warnings and precautions. Graseby and the Smiths Medical design mark
are trademarks of Smiths Medical. The symbol ® indicates the trademark is registered in the
U.S. Patent and Trademark Offi ce and certain other countries. All other names and marks
mentioned are the trademarks or service marks of their respective owners. ©2018 Smiths
Medical. All rights reserved. IN193935GB-082018
Graseby
C9
Syringe Pump
Quick Reference Guide
Alarms Trigger Condition Priority Solution
Battery
Depleted
When an
external power
supply is not
connected, the
battery power is
lower than the
preset threshold
of the battery
depleted.
High
Connect to an
external power
supply as soon
as possible.
Otherwise, the
pump will power
off in 3 minutes.
Transmission
Error
The system
detects that the
syringe plunger
release lever is
open during the
infusion process.
High
Press
to clear
the alarm. Then,
re-clamp the
syringe, and
if the alarm
continues,
please contact
a qualifi ed
technical service
engineer.
System Error
(01-13)
When the
system detects
system faults
such as pressure
sensor
fail-off and
electric motor
abnormality, etc.
High
Restart the
pump.
If the alarm
remains on,
hand it over
to a qualifi ed
technical service
engineer.
IN193935GB-082018.indd 1 23/11/2018 14:31
Question and Answer IconNeed help?

Do you have a question about the Smiths Medical Graseby C9 and is the answer not in the manual?

Smiths Medical Graseby C9 Specifications

General IconGeneral
Volume To Be Infused (VTBI)0.1 to 999.9 ml
VTBI Increments0.1 ml
Battery Life6 hours at 5 ml/hr
Dimensions150 x 80 x 40 mm
Weight400g
Delivery Rate0.1 to 99.9 ml/h
Delivery Rate Increments0.1 ml/hr
Battery TypeRechargeable
Infusion ModeContinuous

Summary

Graseby C9 Syringe Pump Quick Reference Guide

Pump Overview

Control Panel Buttons

Group of buttons for operating the pump, including menu, navigation, OK, return, stop/start, bolus/priming, and power.

Status Indicators

Visual indicators for alarm status, battery charge, and external power supply.

Syringe Mechanism Components

Parts that hold, advance, and release the syringe plunger and barrel.

LCD Display

The main screen displaying pump status, settings, and alarms.

Audio Pause Key

Key to temporarily mute audible alarms.

Power On Procedure

Syringe Loading Steps

Syringe Calibration

Drug Library Management

Enable Drug Library

Steps for enabling the drug library feature within infusion settings.

Drug Library Selection

Procedure for selecting drugs from the organized library categories.

Setting Infusion Mode

Prime the Tubing

Program an Infusion

Change Infusion Rate

Program a Bolus

Manual Bolus

Method for delivering a bolus by holding the bolus key.

Auto Bolus

Method for automatic bolus delivery without holding the key.

End the Infusion

Pump Alarms