ACT925 Operators Manual |
8
ACT925 Operators Manual
| Version 1.0 | Nov. 2019
Cross Sensitivity to
Automotive Chemicals
Some automotive solvents and chemicals have similar hydrocarbon
properties as R134a and may elicit a positive response. Before
leak checking, clean up any chemicals in the list below that elicit a
positive response.
Chemical Name/Brand
Response
Windshield Wash Fluid
Y
Rust Inhibitor
Y
Gasket Adhesive (Wet)
Y
Natural Blue degreaser (diluted)
Y
Brake Parts Cleaner
Y
Silicone Rubber (uncured)
N
Antifreeze heated to 160 deg F
N (partial)
Gunk liquid wrench
Y
Ford silicone lubricant
N
Pumice lotion (with solvent)
Y
Brake fluid
Y
Carburetor Cleaner
Y
Transmission fluid heated to 160 deg F
N
Motor Oil heated to 160 deg F
N
Replacement Parts
Item
Part Number
Threaded Sensor Tip w filter
Instruction Manual ACT925