114
User Code
Code C0
Setting the factory-adjusted modes of operation
(F 5.2.2)
0* = No action
1 = Set default values
(state 1 is only shown briefl y)
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C1
Selecting the resolution of unbalance readings in
1 or 5 g, or 0.05 or 0.25 oz increments
0* = 5 g (0.25 oz) increments
1 = 1 g (0.05 oz) increments
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C2
Selecting suppression of minor unbalance
readings
0 = Suppression off
1* = Suppression on
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C3
Selecting unbalance readings in grammes or
ounces, active when the machine is switched on
0* = Readings in grammes
1 = Readings in ounces
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C4
Electrical compensation of residual unbalance, if
any, in the clamping means
Measurement with increased precision (this mode
cannot be transferred into the permanent memory).
Com
pensation has to be cancelled and carried out
* = Factory adjusted mode