116
User Code
once again when the clamping means is exchanged.
Resetting the status to 0 cancels the compensation of
adaptor unbalance.
The compensation is cancelled by calibration, or
readjustment of the machine, by optimisation, or when
the machine is turned off F 6.1.
Code C5
B
raking of the wheel when the wheel guard is
opened during the measuring run
0 = No braking
THE WHEEL ROTATES WHEN THE WHEEL GUARD
IS OPEN.
MAKE SURE THAT THE WHEEL IS NOT BLOCKED
BY A TOOL OR SIMILAR ITEM.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
1* = Braking
After the con! rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C6
Number of revolutions per measuring run 5 to 25
revolutions possible, factory–set to 10*
Note
Reducing the number of measurement revolutions will
reduce the accuracy
of measurement. The selected
mode of operation can be transferred to the permanent
memory.
After the con! rmation OK, this operating mode can be
acquired in the permanent memory (C10)
Code C8
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grammes, or
ounces. The unit (gms or oz) depends on the
settings made under C3.
Grammes:
Range 3.50 to 20.0 g
Factory-adjusted to 3.5 g
Read out limit, e. g. 3.50 g
Select another limit, e. g. 5.50 g
— Press OK.
* = Factory adjusted mode