Rev. 2
3.5 FIRE AND SMOKE
ENGINE FIRE ON GROUND
Symptoms : ITT increasing, red warning light
ITT
on,
smoke, ...
1 Power lever IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 –”BLEED VALVE switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 –”FREON switch (if installed) OFF. . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Brakes AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Tank selector OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Warn for ground assistance, if necessary
8 CRASH lever PULL DOWN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 EVACUATE as soon as possible
CABIN FIRE ON GROUND
1 Power lever IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Brakes AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Warn for ground assistance, if necessary
5 CRASH lever PULL DOWN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Cabin extinguisher (if installed) AS REQUIRED. . . . . . . . . . . . . . .
7 EVACUATE as soon as possible