T B M
PILOT’S INFORMATION MANUAL 700
SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 3.9.4
Rev. 2
3.9 – ELECTRICAL SYSTEM
AMBER WARNING LIGHT
LO VOLT
ON
functioning on ”ST–BY GENERATOR”
(after ”MAIN GEN” failure)
Amber warning lights
MAIN GEN
and
LO VOLT
ON
with ”GENERATOR” selector on ”ST–BY”
1 –”GENERATOR” selector MAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 –”MAIN GENERATOR RESET” push–button PRESS. . . . . . . . . . .
If successful :
3 – Disconnect ancillary electrical systems not essential
4 – Monitor voltmeter and ammeter
Prepare to SHORTEN FLIGHT
If not successful :
5 –”GENERATOR” selector ST–BY. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 –”ST–BY GENERATOR RESET” push–button PRESS. . . . . . . . .
If successful :
7 – Disconnect ancillary electrical systems not essential
8 – Monitor voltmeter and ammeter
Prepare to SHORTEN FLIGHT
If not successful, both generators failure is confirmed. If possible,
return to VMC conditions