SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
T B M
700 PILOTS INFORMATION MANUAL
Back to
Contents
Page 3.11.3 (b)
Rev. 9 PostMOD7002132
3.11 LANDING GEAR AND FLAPS
DISCREPANCY WHEN
LANDING GEAR GOES DOWN
Red warning light on LANDING GEAR control panel remains
flashing ON (whatever the condition of the green lights may be) :
The red warning light on the landing gear control panel flashing at the
end of maneuver indicates that the landing gear electrohydraulic pump
operates correctly.
1 –”LDG GR circuitbreaker PULL. . . . . . . . . . . . . . . . . . . . . . . . . . . .
If the red warning light goes off :
2 LAND.
If the red warning light remains fixed ON, apply the following procedure :
Red warning light on LANDING GEAR control panel remains
fixed ON (whatever the condition of the green lights may be) :
The red warning light on the landing gear control panel is fixed ON at the
end of maneuver, the green indicator lights are ON or OFF, extend the
landing gear manually.
1 –”LDG GR circuitbreaker PULL. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Floor hatch OPEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Bypass selector FULLY PULL / LOCK. . . . . . . . . . . . . . . . . . . . . .
4 Landing gear control DN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Hand pump ACTUATE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
with maximum amplitude
CAUTION
THE ENTIRE EXTENSION OF THE LANDING GEAR TAKES
ABOUT 65 CYCLES. IT IS MANDATORY TO HAVE A CLEAN
HARDENING OF THE MANUAL CONTROL AT THE END OF
THE MANEUVER