T B M
PILOT’S INFORMATION MANUAL 700
SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 4.3.26
Rev. 6
CHECK–LIST PROCEDURES
MOTORING FOLLOWED BY AN ENGINE START
Within starter operating limits (continuous max. 1 minute), it is possible
to initiate a starting procedure from a motoring procedure.
1 – Engine controls
–”MAN OVRD” control OFF (Notched). . . . . . . . . . . . . . . . . . . . .
CAUTION
WHEN THE ENGINE IS SHUTDOWN, THE POWER LEVER
MUST NOT BE MOVED BEHIND THE FLIGHT IDLE
POSITION
– Power lever IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Flight idle stop)
– Propeller governor lever MAX. RPM. . . . . . . . . . . . . . . . . . . . . .
– Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 – Fuel
– Tank selector L or R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–”AUX BP” switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHTS
AUX BP ON
ON
FUEL PRESS
OFF
3 –”IGNITION” switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 –”STARTER” switch ON during 15 sec. . . . . . . . . . . . . . . . . . . . . . .