SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
T B M
700 PILOT’S INFORMATION MANUAL
Back to
Contents
Page 4.3.33
Rev. 9
CHECK–LIST PROCEDURES
TAKEOFF
WHEN LINED UP
CAUTION
– IF HEAVY PRECIPITATION, TURN IGNITION AND INERT SEP
ON.
– IF ICING CONDITIONS ARE FORESEEN, REFER TO
CHAPTER 4.5, PARAGRAPH ”FLIGHT INTO KNOWN ICING
CONDITIONS”
1 – Heading – HSI – Stand–by compass CHECK. . . . . . . . . . . . . . . . .
– Altimeter setting CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 – Horizon Attitude + 2° – CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 – Lights
–”L.LDG / TAXI / R.LDG” ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 – Engine instruments CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(ITT = green sector)
5 – Advisory panel CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All warning lights OFF,
except
INERT SEP
if used
except
IGNITION
if used
6 – Radar switch (if installed) As required. . . . . . . . . . . . . . . . . . . . . . .
7 – PROP O’ SPEED GOVERNOR TEST
– Increase power until propeller RPM reaches 1900 RPM
– PROP O’ SPEED TEST : Maintain engaged. . . . . . . . . . . . . .
– Observe that propeller RPM decreases of 50 to 150 RPM
– PROP O’ SPEED TEST : Release. . . . . . . . . . . . . . . . . . . . . . . .
– Check that propeller RPM increases again up to 1900 RPM