SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
T B M
700 PILOTS INFORMATION MANUAL
Back to
Contents
Page 4.4.17
Rev. 8
AMPLIFIED PROCEDURES
BEFORE STARTING ENGINE (Contd)
18 –”BAT TEMP TEST pushbutton (if installed) PRESS. . . . . . . . . .
Check illumination of the BAT OVHT warning light on the advisory
panel, check increase of the temperature indicated on the battery
temperature indicator.
19 Passengers briefing AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . .
20 Access door and
(if installed) pilot door
WARNING LIGHT
ÎÎÎÎÎ
ÎÎÎÎÎ
ÎÎÎÎÎ
DOOR
OFF
If DOOR warning light is not OFF, open the access door and (if
installed) the pilot door and reclose it (them). Check locking pins
are in place (green band is visible). Do not take off with DOOR
warning light ON on the advisory panel.
21 Fuel
Gages CHECKED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tank selector L or R CHECKED. . . . . . . . . . . . . . . . . . . . . . .
–”FUEL SEL switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHT
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
AUTO SEL
OFF
–”SHIFT pushbutton PRESS. . . . . . . . . . . . . . . . . . . . . . . . . . .
The selector changes tank
On ground, observe a tank change
every minute and 15 seconds
22 Fuel flowmeter totalizer CHECKED ADJUSTED. . . . . . . . . . . .
Total fuel quantity on board may be set on flowmeter totalizer see
Section 9 Supplements.