T B M
PILOT’S INFORMATION MANUAL 700
SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 4.4.34
Rev. 6
AMPLIFIED PROCEDURES
AFTER STARTING ENGINE
1 – GYRO INST panel
– All switches ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pull on the caging knobs when starting the ADI(s).
2 – Gyroscopic suction gage indicator GREEN SECTOR. . . . . . . . . .
WARNING LIGHT
VACUUM LO
OFF
3 – GYRO SLAVING selector SLAVE. . . . . . . . . . . . . . . . . . . . . . . . . . .
4 – DE ICE SYSTEM panel
Flight into known icing conditions is authorized only when all ice
protection equipment are operating correctly. This equipment may
be activated before takeoff, even during taxiing, in case of icing
conditions on ground. Refer to Chapter 4.5 ”PARTICULAR
PROCEDURES” of this Section.
–”PROP DE ICE” switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check illumination of the green
light located above the switch
Illumination of the green light shows that power supplied to blade
root electric resistors is between 8 and 10 amperes. It is advised to
wait at least a whole half cycle (90 seconds) to check that both
blade pairs are correctly deiced.
–”PROP DE ICE” switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–”L.WINDSHIELD” switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . .