EasyManua.ls Logo

SOCATA TBM 700 - Page 47

SOCATA TBM 700
670 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SECTION 2
LIMITATIONS
D.G.A.C. Approved
T B M
700 PILOTS INFORMATION MANUAL
Back to
Contents
Page 2.4.1
Rev. 2
2.4 STARTER OPERATION LIMITS
Starter operation sequence is limited as follows :
if Ng 30 % 30 seconds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
if Ng > 30 % 60 seconds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Should several sequences be necessary, respect following spacing :
1st sequence
wait 1 minute. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2nd sequence
wait 5 minutes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3rd sequence
wait 30 minutes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4th sequence

Related product manuals