SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
T B M
700 PILOT’S INFORMATION MANUAL
Back to
Contents
Page 3.3.7
Rev. 4
3.3 – ENGINE FAILURES
GOVERNOR REGULATION CONTROL NOT
OPERATING
May indicate a rupture of the linkage of the governor control.
1 – Continue the flight.
2 – If Np < 2000 RPM, do not perform a go–around and do not use the
reverse.
In that case, the go–around performance and the reverse efficiency are
no longer warrantied. The airplane must be repaired mandatorily before
any other flight.