SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
T B M
700 PILOT’S INFORMATION MANUAL
Back to
Contents
Page 3.3.11
Rev. 8
3.3 – ENGINE FAILURES
ENGINE DOES NOT STOP ON GROUND
If the engine does not stop when the condition lever is set to CUT OFF,
proceed as follows :
1 –”AP / TRIMS MASTER” switch OFF. . . . . . . . . . . . . . . . . . . . . . . . .
2 –”RADIO MASTER” switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 – Radar switch (if installed) OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 –”INT. LIGHTS” panel
All switches OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 –”EXT. LIGHTS” panel
All switches OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 –”ECS” panel
All switches OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 – Tank selector OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wait for engine stop due to lack of fuel in the pipes
8 –”GENERATOR” selector MAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 –”SOURCE” selector OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 – Inform the maintenance department