By roof version: maintenance-free
Before unsrewing the cartri-
ge, the hose must be dis-
connected from the cartrige
upwards at the green hose
connection.
Insert black plug in the
green hose connection.
Pull out cartridge and dispo-
se of an appropiate site.
Push in cartrige, pul off plug
(black) upward, and insert
air extraction hose in the
green hose connection.
If you want to change a sec-
ond cassette, then you can
carry the full cassette in the
storage space for several
days. (There is no longer any
gas formation if the cassette
is full)
Œ Before changing the filter, pull the fan out of the rubber sleeve in the filter housing.
Since the filter cartridge push-fits into the pipe, twist it back and forth while pulling it
upwards and out.
Ž Insert the new filter cartridge into the pipe.
You must moisten the rubber sleeve before inserting the fan into the filter cartridge.
Insert the fan as far as it goes, twisting it back and forth.
Only by floor version: Change the filter once a year!
Ventilator
Œ
Ž
˄
Completely unscrew the 2
crosshead screws at the bot-
tom.
Push the cover cap up a little
and remove at the front.
Take out the filter and insert
a new filter into the existing
fitting.
Place cover on the top - pull
it forwards slightly at the
bottom. Push the cover
from top to bottom so that
it locks into place.
Screw in screws and
tighten slightly. Apply a light
pressure on the cover while
doing so.
1
4
2
3
Only by door version: Change the filter once a year!