TROUBLESHOOTING
• The LED should light when the furnace blower is running.
• Both lamps use the same multivoltage ballast.
If the LED does not light: 1. Check to be sure there is power to the unit.
2. Be sure lamp connectors are fastened securely.
3. If the LED still does not light, replace lamp(s).
4. If still not operating, replace ballast.
Note: Standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.
WARRANTY
All electronic components carry a lifetime warranty to the original homeowner. In addition there is a four-year
warranty from the date of installation for any subsequent owner. The manufacturer reserves the right to send
replacement parts or to replace the unit at its discretion. This warranty does not cover any labor or damage
resulting from improper installation or abuse. Use of any lamp other than the manufacturers lamp designed for
this device will void the warranty.
The original lamps are warranted for a period of two years. This warranty does not cover lamps broken during
shipping, installation or as a result of improper handling.
All returns are routed through your contractor/wholesaler and must be approved and accompanied by an RGA#.
Please call 800-578-7873 and we will guide you through the return procedure.
This warranty gives you specic legal rights and you may also have other rights which vary from state to state.
MAINTENANCE
This maintenance schedule is only a guideline, determined by average conditions. Actual conditions will dictate
the frequency of cleaning and/or replacement of lamps. Do not touch the glass portion of the lamps with bare
hands because oils from the hands can cause “hot spots” which reduce lamp life. Handle either by the end caps or
use a soft cloth. If you accidentally touch a lamp, clean it using a soft cloth dampened with rubbing alcohol.
CLEANING THE LAMPS - Recommended interval: 12 months (Follow the procedure below)
Replacement lamps are available through your HVAC contractor.
REPLACING THE LAMPS - Recommended interval: 24 months. (Follow procedure below excluding #6.)
Note: Standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.
1. Disconnect power to the unit.
2. Remove the cover from the unit by removing the four machine screws. Remove the oxidation control (Figure A).
3. Unplug the lamp from each lamp connector.
4. Remove lamp holders using a 1/4 size nut driver (Figure A).
5. Remove each lamp by grasping the end cap and extract carefully.
6. Using a soft cloth moistened with rubbing alcohol, wipe down each lamp. If there is a large build-up of dust
particles, you may wish to use a can of air rst. Always handle lamps by end caps.
7. Slide one lamp back into lamp opening. Reinstall lamp holder.
8. Repeat step 7 for second lamp.
9. Plug each lamp into the corresponding lamp connector.
10. Align the oxidizing control with adjustment linkage and replace cover. (Figure A).
Secure cover using the four machine screws.
11. Restore power to unit.
For Technical Support Call (800)578-7873 © 2018 Form GEN 823 (04/18)
The following parts are included: • FM2 Unit
• Germicidal Twin H Lamp (packed in lamp box)
Four Sheet Metal Screws
Installation & maintenance instructions
Alcohol pad for cleaning lamps
Strain relief connector
When installing and using this electrical equipment, basic safety precautions
should always be followed including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Minimum living space for this product is 1,200 square feet.
3. Always be sure the unit is unplugged during installation or service procedures.
4. The ultraviolet light produced by the UV lamp is harmful to your eyes. Do not look directly at
the lamp. Should it become necessary to view the lamp, use UV-protected sunglasses.
Lors de l’installation et de l’utilisation de cet équipement, des précautions devront être suivies.
1- Lire et suivre les étapes attentivement.
2- Espace minimum d’une habitation pour ce produit est de 1,200 pi. carrés
3- Assurez vous de toujours débrancher avant l installation ou le service.
4- Ne pas regarder la lampe directement avec les yeux. Si nécessaire de le faire,
veuillez porter les lunettes de soleil contre les rayons U.V.
IMPORTANT: SAFETY INSTRUCTIONS
Important: Instructions de securité
3099107
FM2-12, FM2-16
MultiVoltage Oxidizing UVC System
Installation & Maintenance Instructions
UNPACKING THE UNIT
Each unit is shipped with the 5” lamp installed and the germicidal
lamp placed in a box with protective packaging. Carefully
remove lamp from the tube taking care to not touch the glass
portion of the lamp with bare hands. Oils from the hands can
cause “hot spots” which reduce lamp life. Handle by the end
caps or use a soft cloth. If you accidentally touch a lamp, clean it
using the included alcohol cleaning pad or a soft cloth dampened
with rubbing alcohol. The lamp is fragile and proper care must be
taken when removing from packaging.
Question and Answer IconNeed help?

Do you have a question about the solaceair FM2-12 and is the answer not in the manual?

Summary

Troubleshooting

LED Light Functionality

Guidance on troubleshooting the LED light's functionality, including power checks and lamp replacement.

Lamp Compatibility Warning

Warning regarding the use of non-standard lamps voiding the warranty and compatibility issues.

Warranty Details

Component and Lamp Warranty Terms

Details the lifetime warranty for electronic components and a two-year warranty for original lamps.

Return and Repair Procedure

Outlines the process for returning units through a contractor/wholesaler with an RGA#.

Maintenance Procedures

Lamp Cleaning Guidelines

Instructions for cleaning lamps, advising against touching glass with bare hands and using a soft cloth.

Lamp Replacement Steps

Step-by-step guide for replacing lamps, including safety precautions and connector handling.

Unpacking and Initial Handling

Lamp Handling During Unpacking

Guidance on carefully unpacking the lamp, avoiding touching the glass, and using cleaning pads.

Safety Instructions

General Electrical Safety

Essential safety measures to follow during installation and use of the electrical equipment.

UV Lamp Eye Protection

Warning about the harmful effects of UV light on eyes and the need for protective eyewear.

Installation Guide

Optimal Unit Placement

Recommendations for optimal unit placement within the HVAC system, considering air temperature and ozone devices.

Lamp Handling During Installation

Reinforces instructions on proper lamp handling to avoid damage and maintain lifespan, emphasizing end caps.

Mounting and Lamp Connection

Detailed steps for cutting openings, mounting the unit, and connecting the germicidal lamp.

Wiring the Unit

Wiring Connections and Voltage

Instructions for wiring the unit to the furnace blower for proper cycling and voltage requirements.

Activated Oxygen Output

Adjusting Odor Control

Guidance on adjusting the activated oxygen output level using the control lever for optimal air purification.