216
Appendix
Connecting PM+ terminal connector
and ripple control receiver
PIN Assignment Meaning
1 +5V Control voltage for active
power
2 D_IN_1 Level 1
100%
3 D_In_2 Level 2
60%
4 D_In_3 Level 3
30%
5 D_In_4 Level 4
0%
6 +5V Control voltage for reac-
tive power (unused)
Configuration in browser menu
Remote controlled active power reduction Configuration | Feed-in Management | Active Power
Fig.: Channel settings for active power reduction - example 4