6. Maintenance
The solar charge controller is maintenance-free.
All components of the PV system must be checked at least annually, according to the
specifications of the respective manufacturers.
Ensure adequate ventilation of the cooling element.
Check the cable strain relief.
Check that all cable connections are secure.
Tighten screws if necessary.
Terminal corrosion
7. Faults and remedies
Fault Cause Remedy
No display battery voltage too low pre-charge the battery
the external fuse in the
battery connection cable has
blown.
replace the external fuse
battery is not connected unclamp all connections
connect a (new) battery with
the correct polarity
reconnect the solar module
and loads
1.
2.
3.
battery is connected with the
wrong polarity
battery is defective
Info LED flashes
red
charging interrupted due to
excessive charging current
charging automatically con-
tinues as soon as the charging
current lies within the permis-
sible range
Load cannot be op-
erated or only for a
short time
+
info LED flashes
red
load output is switched off
due to excessive load current
reduce load current, if neces-
sary switch off or disconnect
loads
check loads
load output is switched off
due to short circuit at load
output
disconnect loads
correct the cause of the short
circuit
reconnect loads
1.
2.
3.
load output is switched off
due to overheating of the
solar charge controller
the load output automatically
switches on again once the
solar charge controller has
cooled down
improve the cooling air
circulation
remove any other heat
sources
check the conditions of use
and the mounting location
Load cannot be
operated
+
info LED flashes
red
+
red battery LED
flashes
load output is switched
off due to too low battery
voltage
the load output automatically
switched on again as soon as
the battery voltage lies within
the permissible range
pre-charge the battery
equip loads directly con-
nected to the battery with
deep discharge protection
check the battery and replace
if necessary