Safety instruction: Failure to observe this instruction can cause fatal or serious injury.
In the event of fire, use a fire extinguisher suitable for electrical devices.
Only use the device as intended. Ensure terminals do not contact.
Never mount the device where there is a risk of gas or dust explosion.
Do not touch exposed cables with bare hands.
Only use the device in closed, well-ventilated rooms.
Do not operate in salty, wet, corrosive, combustible, or explosive environments.
Connect cables to inverter first, then to battery poles, ensuring correct polarity.
Parallel AC power sources can damage the inverter; use a power transfer switch for safe operation.
Mandatory for mobile units used professionally when 110/230VAC is used externally; RCD not sufficient.
Shuts down output and shows 'fault' if input voltage drops too low after pre-warning.
Shuts down output and shows 'fault' if input voltage rises too high.
Switches off output and flashes 'fault' LED if a short-circuit occurs on the output.
Shuts down output if requested power exceeds continuous power; 'fault' LED flashes.
Problem: 'fault' blinks slowly. Cause: Output short-circuit or overload. Solution: Resolve issue.
Problem: Inverter not functioning, all LEDs off. Causes: No input voltage, fuses, or internal defect. Solutions provided.